top of page
Parts and Service
Components
Generators & Power Systems
Engine

16S CBM unit – Maven Unit
4S CBM unit – Maven Unit

Cell Balancing & Monitoring (CBM) & Maven Unit

-

Applications

Product Availablity 

India

Features & Benefits

    • Control the Pre-Charge, Main Contactors & other
    relays
    • Scalable: Can Control up to 250 CBM units
    • Insulation Monitoring and cut- off
    • Low current consumption
    • Isolated CAN for easy vehicular integration

Related Products

16S CBM unit – Maven Unit
4S CBM unit – Maven Unit

Get Quote

Use the full Product Finder to search or filter by product details.

CBM Specs

-

Cell Voltage Range

1 VDC to 5 VDC

Cell Configuration (Per Slave Board)

6 - 15 cells in series

Balancing Current Per Cell

>100 mA at 5V

Voltage Measurement Accuracy

< ±2.0 mV

Active Mode Current Consumption

14 mA

Communication With Master

RS485

Cell Balancing Detection Voltage

Customizable

Cell Balancing Release Voltage

Customizable

Temperature Sensors

8 nos

Maven Specs

-

Input Voltage

12 to 60 V

High Voltage Measurement Channels

4 isolated channels

High Voltage Measurement Range

0-1000V

High Voltage Measurement Accuracy

±1VDC -40°C to 85°C

Active Current Consumption

32 mA @ 60V & 25°C

Voltage Range (For External Current Sensors)

12-0-12 VDC

Temperature Sensors

4 external

Control Of Number Of Output

4(Isolated)

bottom of page